5 - 116
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Storage item Storage details Reading the monitor value
Md.9
Axis in which
the error
occurred
Stores a number (Axis No.)
that indicates the axis that
encountered an error.
Monitoring is carried out with a decimal display.
Monitor
v
alue
Storage valu
e
1: Axis 1
2: Axis 2
3: Axis 3
4: Axis 4
Md.10
Axis error No.
Stores an axis error No.
Monitoring is carried out with a decimal display.
Monitor value
Error No.
For details on the error Nos.
(Error codes),
refer to section "15.2 List of
errors".
Md.11
Axis error
occurrence
(Hour)
Stores the time at which an
axis error was detected.
Monitoring is carried out with a hexadecimal display.
0
b15 b12
000000000010101
b8 b4 b0
0150
Buffer memory (stored with BCD code)
0 to 2
0 to 3
00 to 23 (hour)
Monitor value
0
015
Not used
Md.12
Axis error
occurrence
(Minute:
second)
Stores the time at which an
axis error was detected.
Monitoring is carried out with a hexadecimal display.
0
b15 b12
100100 100 000 111
b8 b4 b0
9074
Buffer memory (stored with BCD code)
0 to 5 0 to 9
00 to 59 (minute)
00 to 59 (second)
0 to 9
Monitor value
9407
0 to 5
Error history (Up to 16 records can be stored)
Md.13
Error history
pointer
Indicates a pointer No. that
is next to the Pointer No.
assigned to the latest of the
existing records.
Monitoring is carried out with a decimal display.
Monitor value
Storage value
(Pointer number)
0 to 15