5 - 142
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Setting item Setting details
Cd.8
External command valid
•
Validates or in validates external command signals.
•
When changing the "current feed value" using the start No. "9003", use this data
item to specify a new feed value.
•
Set a value within the following range:
Pr.1
mm
(
×
10
-1
µm)
inch
(
×
10
-5
inch)
degree
(
×
10
-5
degree)
PLS
(PLS)
Setting range
-2147483648
to
+2147483647
-2147483648
to
+2147483647
0 to 35999999
-2147483648
to
+2147483647
Cd.9
New current value