5 - 150
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Setting item Setting details
Cd.19
OPR request flag OFF
request
The sequence program can use this data item to forcibly turn the OPR request
flag from ON to OFF.
Cd.20
Manual pulse generator 1
pulse input magnification
This data item determines the factor by which the number of pulses from the
manual pulse generator is magnified.
Value "0" : read as "1".
Value "101" or less: read as "100".
Cd.21
Manual pulse generator
enable flag
This data item enables or disables operations using a manual pulse generator.
Cd.22
New torque value
When changing the "
Md.35
Torque limit stored value", use this data item to
specify a new torque limit stored value.
Set a value within the allowable range of the "
Pr.17
Torque limit setting value".