15 - 17
MELSEC-Q
15 TROUBLESHOOTING
Related buffer memory
address
Axis 1 Axis 2 Axis 3 Axis 4
Set range
(Setting with sequence program)
Remedy
Correct the operation pattern.
(Refer to section 5.3 "
Da.1
")
Same as error codes 515 to 516
Correct the control system.
(Refer to section 5.3 "
Da.2
")
0 150 300 450
<Unit setting>
0, 1, 2, 3
Correct the positioning data or change the parameter
"Unit setting" of the axis to be interpolated.
(Refer to section 9.1.6)
Same as error codes 515 to 516
• Correct the control system.
(Refer to Section 5.3 "
Da.2
")
• Correct the axis to be interpolated.
(Refer to section 5.3 "
Da.5
")
Command speed storage
addresses of positioning
data No. 1 to 600
<Command speed>
1 to 10000000 [PLS/s]
1 to 2000000000 [mm/min or others]
Correct the command speed.
(Refer to section 5.3 "
Da.8
")
29 179 329 479
<Interpolation speed designation
method>
0: Composite speed
1: Reference axis speed
Set the "Interpolation speed designation method"
correctly.
(Refer to section 9.1.6)