6 COOLANT
Mitsubishi Diesel Engine S16R & S16R2 OPERATION & MAINTENANCE MANUAL
114
Pub. No. K29001-00320 Revision: 1
The upper limit of the LLC concentration is 60%
for GLASSY and 90% for PG GLASSY. If the
concentration is higher than above, the
antifreeze effect will be lowered, or the coolant
temperature will be increased due to the lowered
specific heat.
The coolant temperature increases by
approximately 1.5°C [2.7°F] for GLASSY at 60%
concentration and by approximately 3°C [5.4°F]
for PG GLASSY at 90% concentration. Check
heat exchanger capacity of the cooling system to
avoid overheating.
Fig. 6-1 Freezing Temperature of GLASSY
Fig. 6-2 Freezing Temperature of PG GLASSY
When using the other LLC follow the
instruction manual of LLC to be used.
LLC Concentration in Coolant
- Measure
To measure the LLC concentration, the following
tool is required.
Tool: Coolant tester
When using other tools, follow the
instruction manual attached to the tool
to be used.
Tool - Adjust
1 Place 1 or 2 drops of distilled or tap
water on the prism.
Fig. 6-3 Tool - Adjust 1
2 Close the daylight plate slowly.
Fig. 6-4 Tool - Adjust 2
Concentration
Lower Limit
Concentration (Volume%)
Freezing Temperature °C [°F]
0
[32]
-10
[14]
-20
[-4]
-30
[-22]
-40
[-40]
-50
[-58]
-60
[-76]
10 20 30 40 50 60 700
Concentration
Lower Limit
Concentration (Volume%)
Freezing Temperature °C [°F]
0
[32]
-10
[14]
-20
[-4]
-30
[-22]
-40
[-40]
-50
[-58]
-60
[-76]
40 50 60 70 80 90 1000

Table of Contents