EasyManua.ls Logo

Mitsubishi S16R-PTAA2-C

Mitsubishi S16R-PTAA2-C
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 INSPECTION AND MAINTENANCE
Mitsubishi Diesel Engine S16R & S16R2 OPERATION & MAINTENANCE MANUAL
176
Pub. No. K29001-00320 Revision: 1
4 Dry the pre-cleaner naturally and
sufficiently.
Fig. 8-113 Pre-cleaner - Clean 3
5 Check the pre-cleaner for tears.
If a tear or other damage is found, replace
the pre-cleaner with a new one.
6 Install the pre-cleaner (2) on the
silencer.
Check that the hook-and-loop fastener (1) is
retained firmly so that the pre-cleaner will not
drop off.
Fig. 8-114 Pre-cleaner - Install
Air Cleaner - Check and Service
Check the air cleaner for clogging and clean the air
cleaner element.
The air cleaner may be outside the
scope of our supply. For the details,
refer to such a document as the
specification sheet prepared by the
generator manufacturer.
If it is not supplied by SME, follow the
instructions in the supplier's operation
manual.
Air Cleaner - Check for Clogging
Check the air cleaner for clogging.
Air Cleaner Element - Clean
Clean the air cleaner element.
If necessary, replace the air cleaner element with
a new one.
(2)
(1)
Make sure that the air cleaner is free
from clogging.
* Insufficient intake air could result in loss of
power, incomplete combustion, exhaust gas
temperature rise, and overspeed of the
turbocharger.

Table of Contents

Related product manuals