11 TROUBLESHOOTING
Mitsubishi Diesel Engine S16R & S16R2 OPERATION & MAINTENANCE MANUAL
189
Pub. No. K29001-00320 Revision: 1
Troubleshooting
Devices and equipment outside the scope of our supply are included in the facility. For the
details, refer to such a document as the specifications sheet prepared by the generator
manufacturer.
For the devices and equipment outside the scope of our supply, refer the corresponding
manual of the generator and the supplier's operation manual.
Starter Does Not Crank or Cranks Slowly, Resulting in Starting Failure
Table 11-1 Starter does not crank or cranks slowly, resulting in starting failure
Problem Cause Remedies
Reference
Page
Starter does not
crank or cranks
slowly, resulting in
starting failure
Electrical
System
Faulty wire connec-
tion, insufficient ca-
pacity
Check fuse.
Check wiring connection between
battery, starter, and starter switch.
-
Battery charge fault Alternator -Check 178
Check and adjust the belt. 134
136
Capacity degrada-
tion of the battery
Check the level and specific
gravity of the electrolyte
Charge battery.
Replace battery.
177
Faulty starter or
faulty safety relay
Contact your SME dealer. 8
Lubrication
System
Oil viscosity too
high
Change with appropriate engine
oil.
109
155
Excessive oil level Engine Oil Level - Check
Check lubrication system.
157
Engine Body Wear or lock of slid-
ing parts
Contact your SME dealer. 8

Table of Contents