MOBIUSTRIMMER.COM
RECOMMENDED CLEANERS FOR EACH MOBIUS PART:
It is recommended that warm or hot water is used to make up your diluted cleaning solution for the Mobius.
MOBIUS PART RECOMMENDED PH
RANGE OF CLEANER
RECOMMENDED
CLEANER(S)
RECOMMENDED CLEANING PROCEDURE
BLADE SYSTEM
(Helical Blades, Bed Knives,
Spacer Bars)
8.5 – 10 STEP 1 - CLEAN
- Tub O’ Towels Heavy Duty
Cleaning Wipes and/or
- RESIN8 XTRA
STEP 2 - RINSE
with water
STEP 3 - SANITIZE, IF
NECESSARY
- Shyield or Isopropyl
BED KNIVES & SPACER BARS:
With parts on racks, soak in diluted cleaning solution
for 5 – 10 minutes, brush/wipe down any areas with
signicant resin build-up then rinse. Pressure washer OK.
HELICAL BLADES:
Place helical blades in blade racks. If resin build-up
is minimal, simply wipe down with cleaning wipe or
cloth. If resin build-up is more signicant, spray blades
with cleaner, avoiding the bearings on either end, and
let sit for 5 minutes. Brush/wipe down any areas with
signicant resin build-up then rinse. Pressure washer
OK on blades, but not on bearing blocks.
To clean bearing blocks, place blades on support
racks. Use a cleaning wipe to hand-clean bearing
blocks, as necessary
SEPARATOR HOUSING
FAN HOUSING
(Stainless Steel Versions)
10 - 13 STEP 1 - CLEAN
- Super Clean,
- Tub O’ Towels Heavy Duty
Cleaning Wipes and/or
- RESIN8 XTRA
STEP 2 - RINSE
with water
STEP 3 - SANITIZE, IF
NECESSARY
- Shyield or Isopropyl
Spray with diluted cleaning solution, let sit for 5 – 10
minutes, brush/wipe down any areas with signicant
resin build-up then rinse. Pressure washer OK.