Operation
58
04/99 AWB 27-1184 GB
Overview
Table 13: Overview of the operating states
Position of
operating
mode
selector
switch
PLC status
before
action
Action PLC status after action
(DSW = diagnostic status word)
Press
Reset
button
Power
supply off/
on
1(Halt) Run
⫻
– Ready
Ready
⫻
– Ready; DSW acknowledged
1)
Not Ready
⫻
– Ready; DSW acknowledged
1)
Run –
⫻
Ready after remaining cycle processed
1)
Ready –
⫻
Ready
1)
Not Ready –
⫻
Not Ready
––DSW (diagnostic)
––DSW (error)
2 (Run) Run
⫻
– DSW acknowledged
Ready
⫻
– Run (depends on system parameter setup)
1) 2)
Not Ready
⫻
– Via “Ready” to “Run” (depends on setup)
1)
Run –
⫻
Run (with start condition)
1)
, after remaining
cycle processed
Ready –
⫻
Run (depends on system parameter setup)
1) 2)
Not Ready –
⫻
Via “Ready” to “Run”
(acc. to system parameter setup)
1)
3(Run
M-Reset)
Run
⫻
– DSW acknowledged
Ready
⫻
– Run (cold start)
1)
Not Ready
⫻
– Run (cold start)
1)
Run –
⫻
Run (cold start)
1)
Ready –
⫻
Run (cold start)
1)
Not Ready –
⫻
Run (cold start)
1)