the system.
Step 2: How to Test the Temperature of the Shower System:
Follow the steps below to test the the systems water temperature to determine if the highest temperature provided is
to cool or to warm. We do not recommended exceeding a high temperature of 120°F/49°C.
1.Begin the flow of water: Rotate
the Cartridge Ring (B) counter-clockwise until it
stops. Do not loosen the Cartridge Nut (A).
2. Adjust Temperature to Highest Possible Output:
Rotate the Cartridge Stem (C) counter-clockwise until it
stops, this will adjust the water to the warmest
temperature.
3. Measure the water temperature to determine the
output temperature. Once the temperature has been
measured rotate the Cartridge Ring (B) Clockwise to
shut he water flow off.
It is generally not recommended for the water
temperature to exceed 120°F/49°C.
What are your results?
https://solutions.moen.com/Article_Library/How_to_Adjust_the_M-Core_4_Series_Temperature_Limit_Stop
Updated: Fri, 28 Jun 2024 08:16:22 GMT