Page 7
Proame 2 Transmitter
XG0677 - 141231
Operation
Continuous Pilot (CPI) Selection .............
(Optional)
In cold weather climates, the pilot burner can stay
on continuously to prevent condensation or cold air
temperatures near the replace glass. Note, some
jurisdictions do no permit use of continuous pilot system.
Check local codes or contact your Montigo dealer.
WARNING:
Do NOT use CPI with optional Power Vent.
With the system in "off" position press the Mode Key, see
gure 1, to index to the CPI mode icon, see gure 14.
Pressing the Up Arrow Key will activate the Continuous
Pilot Ignition mode (CPI). Pressing the Down Arrow Key
will return to IPI. A single "beep" will conrm the reception
of the command.
NOTE:
- Requires CPI switch (not supplied).
- Set the CPI/IPI switch to CPI position (Switch closed) to
enable remote CPI/IPI operation.
- Set the CPI/IPI switch to IPI position (switch open) to
disable remote CPI/IPI operation. The system will now
work in IPI mode only regardless of the selection on the
remote control hand set.
Figure 14. Continuous Pilot / Intermittent Pilot Selection
Key Lock
This function will lock the keys to avoid unsupervised
operation. To activate this function, press the Mode and
Up Keys and the same time, see gure 15. To de-
activate this function, press the Mode and Up Keys and
the same time.
Figure 15. Key Lock