Installation
The oor at the installation place must be leveled, (even) and capable of bearing corre-
sponding weight. Minor height differences can be compensated by the adjustable feet.
The inner sauna cabin height must be at
least 210 cm.
Observe at least 110 cm clearance between
the upper edge of the heater and the cabin
ceiling. (Fig. 1)
The side (horizontal) gaps between the
heater and the cabin wall or the guard rail,
bench and other ammable materials are
stated in Fig. 2.
The height of the protective heater guard
rail must approximately correspond to the
height in Fig. 3.
Safety gaps
Fig. 1
heater guard rail
12 cm
12 cm
12 cm 12 cm
Fig. 2
guard rail
100 cm
ca. 85 cm
12 cm 12 cm
98 cm
min. 210 cm
35 cm
Fig. 3
!
ATTENTION! Do not operate the heater without feet!
!
ATTENTION! Install only on leveled surfaces! Risk of injuries
through tilting. Ensure vertical position of the heater.