PARAMETERS DESCRIPTION DEFAULT MIN MAX UNIT
11
FC.Y.
Courtesy light setup
0 = On at end of operation for time TCY
1 = On if gate not closed + duration of TCY
2 = On if courtesy light timer (TCY) time not out
0 0 2
12
tC.Y.
Courtesy light on time 0 0 900 s
13
de.a.
Hold-to-run
0 = o
1 = on
0 0 1
14
IN.D.
0 = deactivated
1 = gate open light ON/OFF
2 = gate open light proportional
- Slow ashing with gate opening
- Quick ashing with gate closing
- Steady light if gate open
- 2 ashes + pause with gate stationary (position
other than closed)
3 = Electric lock
4 = Magnetic electric lock function with output active
when gate/door is closed
N.B. interface with an external relay with 24 Vdc
winding. To activate this function, the pre-ash must
be enabled at the recommended value of 1 sec (tP.r.
≠ 0)
0 0 4
15
se.r.
Service interval cycle threshold
(0 = o)
10 0 200
x 1000
cycles
16
se.f.
Enabling of continuous ashing indicating service
required with se.r. ≠ 0 (only active with gate closed)
0 = o
1 = on
0 0 1
17
EL.T.
Electric lock activation time in seconds 2 1 10 s
18
HA.o.
Water hammer on opening
0 = disabled
0 0 100 *100ms
19
HA.c.
Water hammer on closing
0 = disabled
0 0 100 *100ms
20
RE.L.
Motor release from closed/open limit switch. Useful
for lightweight gates
0 = o
1 to 10 release levels (1 = minimum release, 10 =
maximum release)
0 0 10
21
ST.P.
High-speed motor start-up
0 = on
1 = o
0 0 1
22
DM.I.
Leaf 1 closing delay with gate open
0 = O
1 = 1 to 20 Seconds On
1 0 20
23
DE.F.
Reset to default values
1= DUO24
2= RUN24
3= DO NOT USE
4= DO NOT USE
2 1 2
To set the default values: 1) access the advanced programming
function; 2) select the “dEf” parameter”; 3) activate the modication
mode (“0” on display”); 4) accept the modication (press “MENU”
and hold it down). A countdown should now appear: 49,48...,1
down to “don“. Release the button when nished.