EasyManua.ls Logo

Motorola G24 - Turning the G24 on Using ON_N

Motorola G24
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2: Hardware Interface Description
January 1, 2006 Module Hardware Description 15
Figure 2-3 illustrates the G24 power on and off upon application of a power supply, during which
the ON_N or IGN signals are not asserted.
Figure 2-3: Power Supply Turn-on and Off
Turning the G24 On Using ON_N
The ON_N input signal is set high by an internal pull-up resistor whenever a power supply is
applied to G24. Therefore, it is recommended to operate this signal using an open collector/drain
circuit connection.
Asserting the ON_N signal low for a minimum of 500 milliseconds (0.5 seconds) and a maximum
of 1.5 seconds will cause the G24 to turn-on.
Asserting the ON_N signal low for more than 1.5 seconds may cause the G24 to interpret the
signal as a power-off command, and turn off immediately after turning on.
Figure 2-4 illustrates the power-on process using the ON_N signal.
Figure 2-4: ON_N Power On Timing