EasyManua.ls Logo

Motorola G24 - Environmental Specifications G24; Application Interface Specifications G24

Motorola G24
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Environmental Specifications
50 Module Hardware Description January 1, 2006
Environmental Specifications
Table 3-2 gives the environmental operating conditions of the G24 module.
Caution: Exceeding the values may result in permanent damage to the module.
Application Interface Specifications
Table 3-3 summarizes the DC electrical specifications of the application interface connector
signals.
Important: Interface signals that are not used by the customer application must be left
unconnected. G24 incorporates the necessary internal circuitry to keep unconnected
signal in their default state. Do not connect any components to, or apply any voltage
on, signals that are not used by the application.
Important: Signals that are defined as "Do Not Use", or DNU, must remain externally
unconnected in any case. These signals are reserved for future use.
Table 3-2:
Environmental Ratings
Parameter Conditions Min Max Unit
Ambient Operating
Temperature
-20 60 °C
Ambient Extended
Temperature
Functional operation -40
60
-20
85
°C
Storage Temperature -40 85 °C
ESD At antenna connector
Contact
Air
At interface connector
± 6
± 15
± 1
KV

Table of Contents