EDS-408A/405A Series User’s Manual Featured Functions
3-17
Admin Auth. Type (for SNMP V1, V2c, V3, and V3 only)
Setting Description Factory Default
No-Auth
Use admin account to access objects.
No authentication
No
MD5-
Auth
Provide authentication based on the
HMAC-MD5 algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
SHA-
Auth
Provide authentication based on the
HMAC-SHA algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
Admin Data Encryption Key (for SNMP V1, V2c, V3, and V3 only)
Setting Description Factory Default
Enable
8-character data encryption key is the
minimum requirement for data encryption.
Maximum 30-character encryption key
No
Disable No data encryption No
User Auth. Type (for SNMP V1, V2c, V3 and V3 only)
Setting Description Factory Default
No-Auth
Use the admin or user account to access
objects. No authentication.
No
MD5-Auth
Provide authentication based on the
HMAC-MD5 algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
SHA-Auth
Provide authentication based on the
HMAC-SHA algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
User Data Encryption Key (for SNMP V1, V2c, V3 and V3 only)
Setting Description Factory Default
Enable
8-character data encryption key is the
minimum requirement for data
encryption. Maximum 30-character
encryption key.
No
Disable No data encryption No
Trap Settings
Trap Server IP/Name
Setting Description Factory Default
IP or Name
Enter the IP address or name of the Trap
Server used by your network.
None