EasyManuals Logo

Moxa Technologies NPort 5150 User Manual

Moxa Technologies NPort 5150
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #93 background imageLoading...
Page #93 background image
NPort 5000 Series User Manual
93
Pair Connection Slave Mode
When using Pair Connection Mode, you must select Pair Connection Slave Mode for the Operation mode
of one of the NPort device servers. In effect, this NPort will be acting as a TCP server.
Web Interface for the NPort 5100, 5200, and IA5000 Series Only
Web Interface for the Overall NPort 5000 Series
Parameter Setting
Factory
Default
Description Necessity
TCP Alive
Check Time
0 to 99 min 7 min
0 min: TCP connection is not closed due to an
idle TCP connection.
1 to 99 min: The NPort closes the TCP
connection automatically if there is no TCP
activity for the given time.
Required
Local TCP port
TCP port No.
(e.g.,
4001)
4001
This Port No. must be the same port No. that
you set up for the Pair Connection “Master”
device server.
Required

Table of Contents

Other manuals for Moxa Technologies NPort 5150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies NPort 5150 and is the answer not in the manual?

Moxa Technologies NPort 5150 Specifications

General IconGeneral
BrandMoxa Technologies
ModelNPort 5150
CategoryServer
LanguageEnglish

Related product manuals