4. Start-up
4.1 Safety informaon
Read the operang instrucons before
start-up of the magnet device!
A visual check is to be made before start-
up of the complete system!
Ensure that the generator is ghtened
rmly before start-up!
Check the correct t of the drive belts
before start-up!
Only aach load liing magnets to the
system! Operaon for other electrical
users is not permied!
Before beginning work on the enre
system disengage the drive motor!
Never open the terminal connecon box
and the 220 V connector on the generator
and the magnet while the motor is
running!
Fig. 8 | Load liing magnets with various aachments
www.mozelt.com
4.2 Safety regulaons magnet operaon
The operaon of a load liing magnet on a mobile
excavator represents a special mode of operaon and
an increased safety risk. In contrast to working with a
hydraulic grabber, the magnet picks up all available
ferromagnec material immediately aer it is switched
on.
This may even be more than the load-carrying capacity
of the mobile excavator allows.
Similarly, the magnet suddenly releases the lied
material aer it is switched o, if there is cable damage
or a short-circuit in the magnet feed cable. This can
lead to dangerous situaons in the working vicinity, for
example, if falling material causes other objects to be
hurled up by lever force. Furthermore, it is not excluded
that pieces of scrap iron may separate from the magnet
during a swiveling procedure, if these are located at
the lower end of the lied material cluster. For these
reasons, it is parcularly important to observe the
following principle:
While working with the load
liing magnet it is forbidden to
stand within the extended reach of
the excavator
Do not swivel the working equipment
or change the locaon of the
excavator with the magnets
switched on without a
payload - unintenonally
lied materials can lead to
human injury by lever force!
The magnet can oscillate strongly aer load release!
For this reason, the mechanically safe aachment of
the magnet in the form of a special magnet suspension
at the end of the arm on the mobile excavator is highly
recommended!
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
Englisch
MOZELT GmbH & Co. KG
Load liing magnet devices
Technical Manual: Electrical Power Supply T4002
Copyright: MOZELT GmbH & Co. KG, D-47269 Duisburg Edition: May 2012 -8-