11
PV Array Requirements
Serial connection (string) of PV modules
As the core component of PV system, controller could be suitable for various types of PV
modules and maximize converting solar energy into electrical energy. According to the
open circuit voltage (V
oc
) and the maximum power point voltage (V
Mpp
) Ot the MPPT
controller, the series number of different types of PV modules can be calculated. The
below table is for reference only.
SPT-10A
System
voltage
36cell
Voc < 31V
48cell
Voc < 34V
54cell
Voc < 34V
60cell
Voc < 38V
Max.
Best
Max.
Best
Max.
Best
Max.
Best
12V
2
2
1
1
1
1
1
1
24V
2
2
-
-
-
-
-
-
System
voltage
72cell
Voc < 46V
96cell
Voc < 62V
Thin-Film Module Voc>80V
Max.
Best
Max.
Best
12V
1
1
-
-
-
24V
1
1
-
-
-
SPT-10A/SPT-20A/SPT-30A/SPT-40A:
System
voltage
36cell
Voc < 31V
48cell
Voc < 34V
54cell
Voc < 34V
60cell
Voc < 38V
Max.
Best
Max.
Best
Max.
Best
Max.
Best
12V
2
2
1
1
1
1
1
1
24V
2
2
-
-
-
-
-
-
System
voltage
72cell
Voc < 46V
96cell
Voc < 62V
Thin-Film Module Voc>80V
Max.
Best
Max.
Best
12V
1
1
-
-
-
24V
1
1
-
-
-
NOTE: The above parameter values are calculated under standard test conditions (STC
(Standard Test Condition) Irradiance 1000W/m²› Module Temperature25°C › Air
Mass1.5.)