EasyManua.ls Logo

MPPT SPT-10A - Battery Type Configuration; Battery Voltage Parameters

MPPT SPT-10A
157 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
Battery Type
Operating Steps
Under Battery Voltage interface, Iong press ENTER button enter into the interface of
Battery type setting. After choosing the battery type by pressing SELECT button, waiting
for 5 seconds or pressing ENTER button again to modify successfully.
Battery type
1 Sealed (Default)
2 Gel
3 Flooded
Battery Voltage Parameters (parameters is in 12V system at 25°C please use
double value in 24V.)
Battery charging setting
Sealed
Gel
Flooded
User
Over Voltage Disconnect
Voltage
16.0V
16.0V
16.0V
9~17V
Charging Limit Voltage
15.0V
15.0V
15.0V
9~17V
Over Voltage Reconnect
Voltage
15.0V
15.0V
15.0V
9~17V
Equalize Charging
Voltage
14.6V
-
14.8V
Boost Charging Voltage
14.4V
14.2V
14.6V
9~17V
Float Charging Voltage
13.8V
13.8V
13.8V
9~17V
Boost Reconnect
Charging Voltage
13.2V
13.2V
13.2V
9~17V
Low Voltage Reconnect
Voltage
12.6V
12.6V
12.6V
9~17V
Under Voltage Warning
Reconnect Voltage
12.2V
12.2V
12.2V
9~17V
Under Volt. Warning
Volt.
12.0V
12.0V
12.0V
9~17V
Low Volt. Disconnect
Volt.
11.1V
11.1V
11.1V
9~17V
Discharging Limit
Voltage
10.6V
10.6V
10.6V
9-17V
Equalize Duration (min.)
120
-
120
0~180
Boost Duration (min.)
120
120
120
10~180