Warning: The appliance's water protection levels vary across different product zones, as shown in the following
diagram. (The installation regulations comply with IEC 60364-7-702.)
NOTE - The measured zone dimensions are limited by walls and fixed partitions.
Zones
Zone 0
Zone 1
Zone 2
Description of the zones
Zone 0 is the interior of the basin including any recesses in the walls or floor.
Zone 1 is limited by
• Zone 0
• A vertical plane 2m from the rim of the basin.
• The floor or the surface expected to be occupied by the users.
• The horizontal plane 2.5m above the floor or the surface.
Zone 2 is limited by
• A vertical plane external to zone 1 and a parallel plane 1.5m from the former.
• The floor or surface intended to be occupied by the users.