Routine Maintenance Overview Checklist
318 Load Unit Maintenance
79
318 Load Unit: Prevent Rust
Where you operate the load unit determines how often you take rust prevention
measures. Humid and corrosive environments require more prevention.
Recommended
supplies:
#1 grade kerosene
Silicone spray
000 emery cloth
Touchup paint
Metal primer paint
Lint-free cloths
The crosshead can slip if the columns are still damp with kerosene.
You can be hurt and your equipment damaged.
The crosshead locks cannot securely clamp on damp columns. Wait until the
columns are dry to the touch before moving and locking the crosshead.
WARNING
Unpainted surfaces: Spray with silicone, and
then wipe with a clean, lint-free cloth. Or,
wipe with a clean, lint-free cloth dampened
with clean hydraulic fluid.
Chrome plated surfaces: For microscratches,
wipe with a clean, lint-free cloth dampened
with #1 kerosene. For rust discoloration,
polish with a very fine emery cloth, and then
wipe down.
Black oxide surfaces: Spray with silicone, and
then wipe with a clean, lint-free cloth. Or, wipe
with a clean, lint-free cloth dampened with
clean hydraulic fluid.
Painted surfaces: For small scratches, use
touchup paint. For large scratches, sand,
prime, and use touchup paint.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Systems 318 Series and is the answer not in the manual?

MTS Systems 318 Series Specifications

General IconGeneral
BrandMTS Systems
Model318 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals