318 Load Unit
98
Routine Maintenance Overview Checklist
Maintenance
244 Actuator: Maintenance
The 244 Actuator is designed for extended periods of operation without extensive
maintenance requirements.
A summary of the routine maintenance procedures is listed below:
Weekly Clean exposed areas of the actuator piston rod with a clean, dry, lint free rag. If
the actuator is continually exposed to a dirty operating environment, clean the
piston rod on a daily basis.
Monthly Inspect actuator piston rod and seals for excessive wear and/or leakage. Small
scratches in the axial direction of the piston rod or polishing of the rod surface is
considered normal operating wear.
Yearly Change actuator seals if necessary. Actuator assemblies can require more or less
frequent seal changes depending on usage. External oil leakage and/or decreased
performance are indicators of seal wear. Seal replacement is considered a service
procedure; contact you MTS Service Engineer for additional information.
298 HSM: Maintenance
The 298 Hydraulic Service Manifold requires the filter be changed periodically.
Component Identification
Pressure
Accumulator
Return
Accumulator
Inlet
Filter
Dirty
Filter
Indicator

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Systems 318 Series and is the answer not in the manual?

MTS Systems 318 Series Specifications

General IconGeneral
BrandMTS Systems
Model318 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals