336 – AL Wiring Cylinder B6
Yellow alarm; warning
Cause Corrective action
Short circuit in cylinder B6
injector wiring. Result: Misfiring.
1. Check injector wiring.
2. Rectify injector solenoid valve short circuit (positive to negative)
(e.g. by exchanging injectors).
3. Fault is rectified when engine is restarted.
337 – AL Wiring Cylinder B7
Yellow alarm; warning
Cause Corrective action
Short circuit in cylinder B7
injector wiring. Result: Misfiring.
1. Check injector wiring.
2. Rectify injector solenoid valve short circuit (positive to negative)
(e.g. by exchanging injectors).
3. Fault is rectified when engine is restarted.
338 – AL Wiring Cylinder B8
Yellow alarm; warning
Cause Corrective action
Short circuit in cylinder B8
injector wiring. Result: Misfiring.
1. Check injector wiring.
2. Rectify injector solenoid valve short circuit (positive to negative)
(e.g. by exchanging injectors).
3. Fault is rectified when engine is restarted.
339 – AL Wiring Cylinder B9
Yellow alarm; warning
Cause Corrective action
Short circuit in cylinder B9
injector wiring. Result: Misfiring.
1. Check injector wiring.
2. Rectify injector solenoid valve short circuit (positive to negative)
(e.g. by exchanging injectors).
3. Fault is rectified when engine is restarted.
341 – AL Open Load Cylinder A1
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder A1
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.
342 – AL Open Load Cylinder A2
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder A2
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.
60 | Troubleshooting | MS150094/02E 2015-05