343 – AL Open Load Cylinder A3
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder A3
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.
344 – AL Open Load Cylinder A4
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder A4
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.
345 – AL Open Load Cylinder A5
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder A5
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.
346 – AL Open Load Cylinder A6
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder A6
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.
347 – AL Open Load Cylinder A7
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder A7
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.
348 – AL Open Load Cylinder A8
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder A8
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.
MS150094/02E 2015-05 | Troubleshooting | 61
TIM-ID: 0000060724 - 001