349 – AL Open Load Cylinder A9
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder A9
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.
351 – AL Open Load Cylinder B1
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder B1
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.
352 – AL Open Load Cylinder B2
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder B2
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.
353 – AL Open Load Cylinder B3
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder B3
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.
354 – AL Open Load Cylinder B4
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder B4
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.
355 – AL Open Load Cylinder B5
Yellow alarm; warning
Cause Corrective action
Open circuit in cylinder B5
injector wiring. Result: Misfiring.
1. Check injector wiring, exclude disruption in solenoid valve (e.g. by
injector replacement).
2. Fault is rectified after each working cycle.