Section 6
ALBI AQUA – Fault nding
Section6oftheInstallationManualcontainsowdiagramsforidentifyingand
correcting faults within the unit.
WhilstthesectioncontainssomeinformationspecictothepostmixALBI
variants, most of the ALBI AQUA fault conditions are also described, except the
condition described below...
Carbonatorbowllevelsensorcallsforrell
Carbonator pump cuts out after 45 seconds
RedLEDashingatfrontofunit
Stopdispensingdrinksandswitchopoweratmains
Waterowtocarbpumpiseithertooslow
or has stopped
Investigateandcorrectthecauseofinsucient
waterow
Switch on power at mains. Flashing light is cleared
andcarbbowlllswithin45seconds
Continue dispensing drinks
Carbonator pump cuts out within 45 seconds
NoredLEDashingatfrontofunit
Continue dispensing drinks
Carbonator pump starts
Switch on power at mains. Carbonator pump again cuts out
after 45 seconds. Flashing LED returns