17
Section 3
Note:Thecarbonatedwaterowrateshouldbe
setrstandthenthesyrupowrates.
Soda Flow Rate Test Pour:
Ensuring there is a cup under the dispense nozzle,
press the soda button to activate a 7 second soda
test pour.
Measure the volume dispensed, then adjust the
dispensevalveowrate.
See section below: Calculation of carbonated water
ow
The Albi unit nished drink ow rate is typically designed to pour at 1.5oz/sec.
(42.5ml/sec.) @ 5:1 syrup ratio.
Thisisanexampleofhowtheowratesarecalculated:
((Flow rate per second / the total parts of the ratio) x (parts of the ratio for carb/still
water)) x 7 second pour
For1.5ozpersecondnisheddrink,@5:1ratio,thewaterowratecalculationisas
below:
((1.5oz per sec. / 6 total ratio parts) x (5 parts of the ratio)) x 7 seconds = 8.75oz
(246ml)
Once the still water ow rate is set, now set the syrup ow rates:
Calculatethesyrupowvolumeforthe7secondtestpour:
Examplecalculationfor1.5ozpersecondnisheddrink,@5:1ratio:
(1.5oz per sec. / 6 total ratio parts) x 7 seconds = 1.75oz (49.6ml)