EasyManuals Logo

Munters MLT350 User Manual

Munters MLT350
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
DehumidierML420-MLT1400
Partnumber170-013448–005170-013448–004170-013448–003170-013448–002170-013448–001
A
Ø100Ø125Ø160Ø200Ø250
B
Seesection9.1,Dimensionsandservicespace.
L(mm)
210210200140150
ML420XX
ML690XX
MLT800XX
ML1100XX
ML1350XX
MLT1400XX
CA CA
CA
UTION! UTION!
UTION!
Thedehumidierhasbeendesignedtooperateatspecicprocessairowscorrespondingtothefansizes
installed.
Theprocessairanddryairductsshouldbethesamediameter.Thesameappliestothereactivationair
andwetairducts.
Thelengthofductworkmustbekeptasshortaspossibletominimisestaticairpressurelosses.
Tomaintainperformance,allrigidprocessorreactivationairductworkjointsmustbeairandvapour
tight.
Theprocessairductworkmustbeinsulatedtopreventcondensationdevelopingontheoutsideofthe
duct,wheneverthetemperatureoftheairwithintheductfallsbelowthedewpointtemperatureofthe
ambientairthroughwhichtheductworkisrouted.
Theductsmustalwaysbeinsulatedwhenthereisariskoffreezing.
Thewetairleavingthedehumidierwill,becauseofhighmoisturecontent,condenseontheinsideduct
walls.Byinsulatingtheducts,theamountofcondensateisreduced.
Horizontalwetairductsmustbeinstalledwithaslightdecline(awayfromthedehumidier)todrain
awaypossiblecondensation.Suitablecondensationdrainsmustbeinstalledatlowpointsinthewet
airoutletduct,seeFigure4.7.
Ensurethataccessforoperationandservicingisnotrestrictedwhendesigningandinstallingducting.
Formoreinformation,refertosection9.1,Dimensionsandservicespace.
Toreducenoiseand/orvibrationbeingtransmittedalongrigidducts,goodquality,airtightexible
connectionscanbetted.
Ductsmounteddirectlyontotheunitmustbeindependentlysupportedtominimisetheloadontheunit.
Dampersforadjustingtheairowsmustbeinstalledinthesupplyairoutletandreactivationairinlet
ducts.Correctairowsareessentialfortheoperatingefciencyoftheunit.Forairowadjustment
instructions,seesection5.3,Airowcheckandadjustment.
Thetotalpressuredropintheprocessandreactivationductworkmustnotexceedtheavailablepressure
ofthefansttedtothedehumidier.Fordetailsofminimumavailablestaticpressure,seesection
9.3,Technicaldata.
10Installation190TGB-1035-H1604