3-3
Machine Parameter A:0
Switch
Initial
Setting
Adjust Usage/Comments
7 0
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Country code The country code enables the ROM to output the
correct programming information for the respective
country.
Machine Parameter A:1
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Non-loaded cable
compensation (TX)
0: 0: 1: 1:
0 db 4 db 8 db 12 db
6 1 0: 1: 0: 1:
5 0 Non-loaded cable
compensation (RX)
0: 0: 1: 1:
0 db 4 db 8 db 12 db
4 1 0: 1: 0: 1:
3 *
2 *
1 *
0 *
Output attenuation See table below
Note: The setting of this switch is available only
when setting other than 0 dB and this setting is
used instead of Memory Switch B:1, bit 3-0.
Machine Parameter A:1…Output attenuation
Switch -15
dB
-14
dB
-13
dB
-12
dB
-11
dB
-10
dB
-9
dB
-8
dB
-7
dB
-6
dB
-5
dB
-4
dB
-3
dB
-2
dB
-1
dB
-0
dB
3 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
2 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0
1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0