Installation and commissioning 7
Example, Dynamic Milk: all drains must be sloped.
Attach the drain tube and rinse hose to the connection angle using cable ties
Caution
To prevent back-contamination, the hoses MUST NOT make contact with the wastewater.
Two position arrows are inscribed on the elbow connector for reference.
Connect to the power supply
Switch on the coffee machine
1.2.2 Recommended water filter
When the carbonate hardness is above 5 °dKH, a WMF water filter should be installed.
For the WMF 1500S+, – bestmax M – is recommended in the standard in the retail price list.
After measuring the carbonate hardness with a test kit - which is within the sell-by date - cut to size according to the capacity table
(see the User Manual which comes with the filter).