Input AC 115/230V
Output DC 24-28V
Output Current 1.3A @ 24V
1.0A @ 28V
Power 30W
35 mm DIN-Rail Mountable
Dimensions: 45X75X91 mm
7026TX with AC Power Supply Installed
Unscrew & Remove the AC Voltage Input
Plug from the Power Input Header
Install the AC Power Cables into the Plug
(observing polarity).
Plug the Voltage Input Plug back into the
Power Input Header.
Tightening torque for the terminal block
power plug is 0.5 Nm/0.368 Pound Foot.
Verify the Power LED stays ON.
When an AC Power supply is installed (i.e., the AC option), Use 12-24 gauge wire when
connecting to the power supply.