ElectricalInstallaonManualU-30“D”Control www.NabcoEntrances.com
Part #C-00121 Rev. 8-25-16
6-22 InfraredBeamWiring
► Emitter
►
►
system to stop operating until the Slide door is repositioned and latched. Please see .
MOTOR/OPERATOR
P/N 24-11327
U30 MICROPROCESSOR CONTROL
P/N 24-8901-30
POWER SUPPLY
P/N 14-11741
TB1
NOISE
FILTER
TB2
T1
S1
PE
N
L
LOAD
-CIRCUIT-
-BREAKER-
RED INDICATES
POWER IS OFF
PRESS
TO
RESET
POWER SUPPLY
ASSEMBLY
P/N 9418800100
NABCO
14-11741
ENTRANCES, INC.
0
7
1
2
3
4
5
6
7
8
9
10
1
1
12
>POM<
N
A
B
CO
GYRO T
E
C
H
D
S
-
1
5
0
0
D
2
4
-
11
3
2
7
0
N
a
bte
sco
C
o
rp
o
ra
t
i
o
n
M
A
D
E
I
N
J
A
PA
N
N
AB
C
O
N
A
B
CO
CAUTION
!
RELATED DEVICE
S
・
16
P
12
13
14
15
16
No.
11
10
9
8
7
6
5
4
3
2
1
SYMBOL
H
M0
9DC12V
SQ
OU T
Common
N/C
N/O
OUT. A
OUT. B
OUT. C
7
BA
62
SLS
M1
6B
7
61
Sequenal Acvaon
Auxiliary Output (Open-Collector)
5Amax.(0-20V), 3.2Amax.(20-30V
)
30V(42.4Vpeak)max
Contact Output (Class2 Load only)
12VDC-(Common)
FUNCTION (SLIDING DOOR)
Reduced Opening Switch
Breakout Detector
Sidelite Presence Sensor
Exterior Acvaon
Holding Beam
Interior Acvao n
12VDC-(Common)
12VDC +
Mode Switch (see Mode SW Usage shown le)
HANDY
TERMINAL
6P
No.
248901-
Microprocessor Controller
Mode SW Usage
Gnd
GndGn d
Open
Open
Open
Gnd
Open
M0
M1
MODE
TWO WAY
ONE WAY
NIGH T
HOLD OPEN
To protect against risk of Fire
or electric shock,use only the
cerfied NABCO power supply.
WARNING
MOTOR 12P
ERROR
POWER
BA
62
H
6B
61
INDICATORS
POWER2P
Do not disassemble the control box.
There are no user serviceable parts
inside.
To maintain warranty,repairs must be
made by authorized NABCO facilities.
Adjustments to the door can only be made
with the NABCO Handy Terminal.
20VA C 50/60Hz
GYRO TECH
NABCO
!
!
!
!
12VDC Common
12 VDC+
12VDC-
(Common)
Holding Beam
Reduced Opening Switch
Mode Switch
Breakout Detector
Sidelite Presence Sensor
Contact Output
(Class2 Load only)
30V (42.4V peak) max.
5A max, (0-20V), 3.2A max.
(20-30V)
Auxiliary Output
(Open Collector)
N/O
N/C
Common
9DC 12V
7
61
6B
H
M0
M1
62
SQ
BA
SLS
Out.A
Out.B
Out.C
Out
7
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Related Devices - 16P
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
DN 0550
CONNECT
EACH TERMINAL
THE SAME
Braided Shield
Yellow
Jacket Color
TERM #13
TERM #6
TERM #5
TERM #1
Optex OS-12C
Controller
P/N 14-9710-03
BLUE
TERM #6
YELLOW
TERM #7
GRAY
TERM #10
YELLOW
TERM #11
RED
GRAY
EMTR 1
BLUE
RCVR 1
U30 MICROPROCESSOR CONTROL LABELU30 TERMINAL
P/N 14-11873
BROWN & RED
CIRCUIT 1 & 2
OTHER WIRES NOT SHOWN
FOR SIMPLICITY
± 10%
50 / 60 Hz
BLUE