ALIGNMENT
PROCEDURE
REQUIRED
INSTRUMENTS:
SPECIAL
JIG
(SEE
FIG.1)
OSCILLOSCOPE
(BANDWIDTH
GREATER
THAN
40
MHz)
FREQUENCY
COUNTER
TEST
DISK
(SONY
YEDS-7)
NOTE
Exact
adjustment
can
only
be
performed
with
special
factory
jigs
etc.
However
the
following
alignment
procedure
should
produce
a
wel]
aligned
player
assuming
no
fault
conditions
are
present.
It is
suggested
that
the
position
of
the
preset
resistors
setting
is
noted
or
marked
before
any
adjustment
is
attempted
so
that
these
settings
can
be
returned
to,
should
no
improvement
be
noted
after
adjustment.
Please
refer
to
page
12
for
the
physical
location
of
the
adjustment
and
test
points.
Step
A:
)
)
)
)
)
NNN
NN
oR
OM
Step
B:
~~
oN
nN
(3)
Step
C:
(1)
(2)
PLL
Adjustment
Turn
power
ON
and
press
the
STOP
key.
Short
circuit
P108
(ASSY)
to
P107
(GND)
Connect
the
frequency
counter
to
P106
(CLK)
and
P107
(GND)
Adjust
RV101
for
a
reading
of
4.2318+
0.01MHz.
After
adjustment
is
completed
remove
the
short
circuit
between
P108
and
P1i07.
RF
Adjustment
Load
the
test
disc
and
set
the
unit
into
PLAY
mode.
Connect
the
scope
to
P109
(RF)
and
P107
(GND).
Scope
setting:
Coupling
:
AC
Vertical
sensitivity:
0.2V/div
Horizontal
time
base:
0.5uS/div
Adjust
RV102
so
that
the
3T
component
of
the
waveform
is
maximun
and
the
eye
pattern
is
at
its
best
shape
(see
Fig
2)
EF
Balance
adjustment
Turn
the
power
OFF,
remove
P1i11
and
replace
it
with
the
special
jig
shown
in
Fig
1.
Connect
the
scope
as
shown
Fig
1.
and
switch
the
jig
to
the
“ON”
position.
scope
setting:
Coupling
:
DC.
Vertical
sensitivity:
0O.5V/div.
Horizontal
time
base:
2
mS/div.

Other manuals for NAD 5420