EasyManuals Logo

NAPCO Gemini GEM-P3200 User Manual

NAPCO Gemini GEM-P3200
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
L NAPCO Security Systems
X GEM-P3200 Programming Instructions
Page 11
WI1184B 2/06
Example: Program a code of “2222” for user 02, with User Option of “User Program”, User “Level 3” and Access Control Option
“Keypad No. 1”. Enter “2222” for a user code, “2 3” for user option and “blank(•) 1” for access control option.
CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described
above and press
U to save. Similarly, to cancel a code, blank out each number of the code and press U to save to
save.
USER AUTHORITY LEVEL
FUNCTION LEVEL*
DISPLAY ZN FAULTS
1
DISPLAY ZN BYPASSED
1
DISPLAY ZN DIRECTORY
1
ACTIVATE BELL TEST
1
DISPLAY PHONE #’S
1
DISPLAY SYS TRBL
1
DISPLAY FIRE ALARM
1
DISPLAY FIRE TRBL
1
DISPLAY OP/CL
3
ACTIVATE OVERVIEW
3**
ACTIVATE CHIME
1
ACTIVATE WATCH
2
RESET SYSTEM TRBL
3
RESET SENSOR MSG
3
START EXIT TIME
1
FAULT FIND
***
ACTIVATE LOCATE
***
EZM ZONE FIND
***
ACTIVATE DIALER TEST
3
DISPLAY ALARM LOG
3
DISPLAY TOTAL LOG
3
DISPLAY FIRE LOG
3
DISPLAY OP/CL LOG
3
DISPLAY SYSTEM LOG
3
AUTOARM IN 1-4HRS
2
DISPLAY AUTOARM SCHD
3
ACTIVATE PROGRAM
3**
ACTIVATE DOWNLOAD
3
DISPLY RF XMITTER STAT
1
RELAY CONTROL
1
KEYPAD DISPLAY FUNCTION MENU
NOTES:
* Minimum Level required to access function
** Level-3 Code with appropriate user option
*** Requires Dealer Code
Related User Options: “Ambush Code” (Address 0495), “Panel Access
Code” (Address 0490), “Dealer Security Code” (Address 0500) & “Enable User Code by
Area” (Address 2500-2595).
OPTIONS EXPLANATION
Disabled User Code not active in this area.
Blocked View Allows User Code to block another code from being viewed by another user.
An unblocked code cannot view a blocked code, but a blocked code can
view all codes. The master user code and the dealer program code can view
all codes.
User Program User Program Option is enabled for Keypad 1 only, wherever it is connected
(any area). If enabled, Level 3 must also be enabled.
Bypass Allows User Code to bypass zones.
Overview This option, along with Level 3 Authorization, enables selection of
OVERVIEW mode at a keypad. This Mode provides a system status display
of all areas at a glance.
Arm Only Prevents User Code from disarming this area.
Service A Service Code has restricted arm/disarm rights; if an area is armed with a
Service Code, a
SERVICE ON” appears on the GEM-RP2ASe2 keypad (a “S
on the GEM-RP1CAe2 keypad) and the area can be disarmed with any valid
User Code, including a Service Code. If the area is armed with OTHER than
a Service Code, it CANNOT be disarmed with a Service Code. This is
typically used to allow tradesmen access to premises under control of the
owner.
Access This is normally used to activate a door striker while an area is disarmed. A
code with the access option will not function as an arm/disarm code. When
the code is entered, the keypad will display “
ENTER NOW” and the Brown
Wire on the keypad will become Active Low (Ground Potential) for 7
seconds.
USER OPTIONS
Ambush
There are two types of Ambush Codes: (1) A 2-digit code (prefix) that is entered
immediately prior to (and as part of) the regular User Code and (2) A separate
and unique User Code. Disarming with an Ambush Code will cause a silent
report to be sent to a central station. Thus, should a user be forced to disarm, he
can silently signal an emergency while appearing to be merely disarming the
system.
GEM-RP2ASE2/GEM-K2AS KEYPAD EASY PROGRAM MENU

Table of Contents

Other manuals for NAPCO Gemini GEM-P3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO Gemini GEM-P3200 and is the answer not in the manual?

NAPCO Gemini GEM-P3200 Specifications

General IconGeneral
BrandNAPCO
ModelGemini GEM-P3200
CategoryControl Panel
LanguageEnglish