NAPCO Security Group
NAPCO Gemini C-Series Control Panel Programming Instructions--Volume 1
Page 22 Programming Instructions, Volume 1
ACTIVATE
DIALER TEST Y/N
DISPLAY
ALARM LOG Y/N
DISPLAY
TOTAL LOG Y/N
DISPLAY
OP/CL LOG Y/N
DISPLAY
SYSTEM LOG Y/N
TO ARM IN 1-4 HRS
PRESS 1-4 /N
ACTIVATE
PROGRAM Y/N
ACTIVATE
DOWNLOAD Y/N
DISPLAY RF
XMITTER STAT Y/N
problem, call for service.
Activate Telephone Test? (Telephone Test programmed? YES NO). (
Master
Security Code or Dealer Keypad Program Code required to view this function
) Sends a communicator test to the
Central Station. A communication failure will be indicated at the keypad by a system
trouble "E03-FAIL TO COMM" display. Repeat the test to attempt to correct a
communication failure, as any successful communication will clear this display.
Display Alarm Log (
Master Security Code or Dealer Keypad Program Code required to view this function)
Displays most recent alarm events. Line 1 displays event and date; line 2 displays time,
area and zone. To check previous alarm events, scroll back using the PRIOR button.
Display Total Log (
Master Security Code or Dealer Keypad Program Code required to view this function)
Displays most recent events of all types. Line 1 displays event and date; line 2 displays
time and, if applicable, area and zone or user. To check previous events, scroll back
using the PRIOR button.
Display OP/CL Log (
Master Security Code or Dealer Keypad Program Code required to view this function)
Displays most recent openings and closings. Line 1 displays event and date; line 2 dis-
plays time, area and user. To check previous events, scroll back using the PRIOR but-
ton.
Display System Log (
Master Security Code or Dealer Keypad Program Code required to view this function)
Displays most recent system events. Line 1 displays event and date; line 2 displays
time and other pertinent information, where necessary, depending upon event. To
check previous system events, scroll back using the PRIOR button.
Delay Arming 1-4 hours. (Not for UL-listed systems). (
Master Security Code or Dealer Keypad
Program Code required to view this function
). Your system may be set to arm automatically after a
delay period of 1 to 4 hours.
To Delay Arm the system:
With the function "TO ARM IN 1-4 HRS" displayed in the window, enter the desired
Delay Arming time in hours (
1, 2, 3,or 4), followed by U.
At the end of this 1 - 4 hour Delay Arming period, the siren will sound a 2-second
warning and the keypad will begin a 15-minute arming countdown with the sounder
pulsing. The sounder may be silenced at this time by pressing RESET, but it will turn
back on with a steady warning tone 1 minute prior to arming, at which time the building
must be exited. The same steps can be used to delay a scheduled Auto Arming, if your
system has been programmed as such.
Activate Program? Activates the Program Mode from Keypad No. 1. (
Master Security
Code or Dealer Keypad Program Code required to view this function
). Note: This feature is disabled while
armed (see PROGRAMMING USER CODES). If the system includes Fire Alarm pro-
tection in addition to Burglary Alarm protection, see the GEMC-FK1 (Fire Keypad) User
Guide (OI341).
Activate Download? (
Master Security Code or Dealer Keypad Program Code required to view this function). If
accidentally enabled, press
C to exit. Note: This feature is disabled while
armed.
Display RF XMITTER Stat? (
Master Security Code or Dealer Keypad Program Code required to view this func-
tion
). Press YES to check the status of up to 255 transmitters. The keypad will display:
Zone number (Z01-Z96)
Transmitter ID code number (6 digits)
Point number (PT1 - PT4; "9" for unsupervised)
FUNCTION MENU -- BURGLARY KEYPAD (CONT'D)