When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific recommendations
from the local authority having jurisdiction, the certified high altitude input rating shall be reduced at the rate of 4% for each
additional 1,000ft (305m). Expansion / contraction noises during heating up and cooling down cycles are normal
and are to be expected. Change in flame appearance from “HI” to “LO” is more evident in natural gas than in
propane.
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is certified for mobile
home installation.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.
The protective wrap on plated parts is best removed when the assembly is at room temperature but this can be
improved if the assembly is warmed, using a hair dryer or similar heat source.
This appliance is a decorative product. It is not a source of heat and not intended to burn solid fuel.
note:
Batteries must be disposed of according to the local laws and regulations. Some batteries may be
recycled, and may be accepted for disposal at your local recycling center. Check with your
municipality for recycling instructions.
1.1 rates and specifications
AX36-1 AX42-1
Fuel Type
Natural Gas Propane Natural Gas Propane
Altitude (FT)
0-4,500
Max. Input (BTU/hr)
35,500 34,000 38,000 36,500
Min. Inlet Gas Supply Pressure
4.5” w.c. (11mb) 11” w.c. (27mb) 4.5” w.c. (11mb) 11” w.c. (27mb)
Max. Inlet Gas Supply Pressure
7”* w.c. (17mb) 13” w.c. (32mb) 7”* w.c. (17mb) 13” w.c. (32mb)
Manifold Pressure (Under Flow
Confictions)
3.5” w.c. (9mb) 10” w.c. (25mb) 3.5” w.c. (9mb) 10” w.c. (25mb)
Installer: please fill out appliance checklist
in the Owner’s manual.
*Maximum inlet pressure not to exceed 13”.
This appliance is suitable for use with the Universal Heat Management system. THIS MANUAL DOES NOT
include detailed information relating the optional sytem. Framing and finishing are NOT the same. For further
details, refer to UHM instructions provided with the kit before starting installation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Napoleon Altitude AX36NTE-1 and is the answer not in the manual?

Napoleon Altitude AX36NTE-1 Specifications

General IconGeneral
BrandNapoleon
ModelAltitude AX36NTE-1
CategoryIndoor Fireplace
LanguageEnglish

Related product manuals