IBIC Section Five
GPIB-PC User Manual 5-4 ©National Instruments Corp.
Using IBWRT
The IBWRT command sends data from one GPIB device to another. For
example, to send a data string from the computer to a device called
dev1, the following command would suffice:
Example:
dev1:
[0100] (cmpl)
count: 6
ibwrt "F3R5T1"
This command sends the string "F3R5T1" to device called dev1. The
returned Status Word [0100] indicates a successful I/O completion,
while the Byte Count indicates that all six characters were sent from
the computer and received by the device.
Using IBRD
The IBRD command causes a GPIB device to receive data from another
GPIB device. The following example illustrates the use of the IBRD
function.
Example:
N D C V ( 0 0 0
. 0 0 4 7 E + 0
• •
dev1:
[2100] (end cmpl)
count: 18
4E 44 43 56 28 30 30 30
2E 30 30 34 37 45 2B 30
0D 0A
ibrd 20