Section Two Installation and Configuration
©National Instruments Corp. 2-9 GPIB-PC User Manual
device is automatically terminated when END is received. No
end-of-string character is recognized.
The time limit on I/O and wait function calls is approximately
10 seconds.
GPIB0 is a Model GPIB-PCII, is at base I/O address hex 02B8,
and uses DMA Channel 1 and TLC Interrupt Line 7.
You must run IBCONF if you are using a GPIB-PCIIA or if you
have changed the hardware switches/jumpers on any GPIB-PC
from the factory settings. Otherwise, it is unnecessary to run
IBCONF. Consult the appropriate supplement to Section Two
of the user manual to find the factory settings of your GPIB-PC
model.
Running IBCONF
When you ran IBSTART, a copy of IBCONF.EXE was placed on your
boot drive.
To run IBCONF, go to the root directory of the boot drive and enter:
ibconf
If you have a color monitor, the configuration program will
automatically appear in color. If you have a color monitor but want the
configuration program to appear in monochrome, enter:
ibconf -m
IBCONF scans the handler file, GPIB.COM, and reads its data structures
into memory. After you press a key, the program displays the Device
Map for board GPIB0.