Whydoesn'tmyserialENETinterfaceshowup
intheNIEthernetDeviceConfigurationutility?
Allowatleast90secondsfortheserialdeviceservertocompleteits
power-onselftestsbeforelaunchingdeviceconfigurationorclicking
Refresh.
CommunicationbetweentheNIEthernetDeviceConfigurationutilityand
theserialdeviceserverisnotguaranteed.Thoughunlikely,itispossible
thatthecommunicationgetslostinthenetwork.ClickRefreshmorethan
oncebeforeconcludingthatthedeviceisnotdiscovered.
Verifythattheserialdeviceserversharesthesamesubnetasthe
computerrunningtheNIEthernetDeviceConfigurationutility.TheNI
EthernetDeviceConfigurationutilitycannotcommunicatewithdevices
throughgatewaysonthenetworkandwillnotdiscoverdeviceson
anothersubnet.