62 Installing a Cascade System
System Application #1- Cascade System with Closely Spaced Tees
12” (30 cm)
maximum
Air separator
Sub2Sub1
Main
Temperature
sensors (required)
Cold water
Supply
Return
Back flow preventor
Expansion tank
Note
Connect the “SH Demand (SH T/T or Zone controller)” to the main unit.
Connect the supply/return sensors to SUPPLY and RETURN terminals of the CNT1/2 terminal strip on the main unit PCB.
Connect the outdoor sensor (optional) to the main unit.
Install system pumps to the units (main and sub) as required by the system configuration.
System Application #2- Cascade System with Hydro Separator
Sub2
Sub1
Main
Cold water
Supply
Return
Dirt collector
Hydro/Air separator
Back flow preventor
Expansion tank
Temperature
sensors (required)
Note
Connect the “SH Demand (SH T/T or Zone controller)” to the main unit.
Connect the supply/return sensors to SUPPLY and RETURN terminals of the CNT1 terminal strip on the main unit PCB.
Connect the outdoor sensor (optional) to the main unit.
Install system pumps to the units (main and sub) as required by the system configuration.
Connect zone pumps to the main unit, or to the zone controller.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navien NFB Series and is the answer not in the manual?

Navien NFB Series Specifications

General IconGeneral
TypeCondensing Boiler
Fuel TypeNatural Gas or Propane
Heat ExchangerStainless Steel
Vent TypeDirect Vent
Vent Diameter2" or 3"

Related product manuals