16 Troubleshooting
5.2 Understanding Error Codes
When an error code appears on the front panel, refer to the following chart for a definition and possible remedy for the situation.
Error Code Reason Self-diagnostic / Action
E003 Ignition failure
Ɣ
Ensure that the main gas supply valve is open.
E004 False flame detection
Ɣ
Ensure that the electrical cord is properly grounded.
E012 Flame loss
Ɣ
Clean the intake air filter. See page 13.
Ɣ
Ensure that the electrical cord is properly grounded.
E016 Overheating of heat exchanger
Ɣ
Turn off the system for at least 30 minutes, and then restart it.
Ɣ
Clean the cold water inlet filter. See page 12.
Ɣ
Flush the heat exchanger. See page 11.
E030
Exhaust overheating (the water heater shuts down
when the flue temperature exceeds 149 °F (65 °C)
Ɣ
Turn off the system for at least 30 minutes, and then restart it.
Ɣ
Clean the cold water inlet filter. See page 12.
Ɣ
Flush the heat exchanger. See page 11.
E046 Abnormal operation: limit control Contact Technical Support at 1-800-519-8794.
E047 Abnormal operation: exhaust thermostat Contact Technical Support at 1-800-519-8794.
E060 Abnormal operation: dual venturi Contact Technical Support at 1-800-519-8794.
E109 Abnormal operation: fan motor Clean the intake air filter. See page 13.
E110 Abnormal air pressure
Ɣ
Ensure that the exhaust pipe is free of obstructions.
Ɣ
Clean the intake air filter. See page 13.
E407 Hot water outlet: thermistor open or short circuit Contact Technical Support at 1-800-519-8794.
E421 Cold water inlet1: thermistor open or short circuit Contact Technical Support at 1-800-519-8794.
E432 Cold water inlet2: thermistor open or short circuit Contact Technical Support at 1-800-519-8794.
E434 Abnormal operation: water adjustment valve Contact Technical Support at 1-800-519-8794.
E438 Abnormal operation: circulation pump
Ɣ
External: Ensure that all water supply and return lines are open.
Ɣ
Internal: Check the direction of the 2-way valve.
E439 Abnormal operation: flow sensor Contact Technical Support at 1-800-519-8794.
E441 Hot water inlet2: thermistor open or short circuit Contact Technical Support at 1-800-519-8794.
E445 Abnormal operation: Bypass mixing valve Contact Technical Support at 1-800-519-8794.
E515 Abnormal operation: PCB Ensure that the electrical cord is properly grounded.
E517 Abnormal operation: DIP switch setting Contact Technical Support at 1-800-519-8794.
E593 Abnormal operation: front panel key Contact Technical Support at 1-800-519-8794.
E615 Abnormal operation: input and memory Contact Technical Support at 1-800-519-8794.
E736 Abnormal operation: cascade communication Contact Technical Support at 1-800-519-8794.
E740 Abnormal operation: outdoor temperature sensor Contact Technical Support at 1-800-519-8794.
E760 Flushing/service alarm Contact the installer to perform routine service.
E782 Abnormal operation: main panel communication Contact Technical Support at 1-800-519-8794.
E785 Abnormal operation: flow switch/sensor Contact Technical Support at 1-800-519-8794.
If any of these remedies do not resolve the problem, contact Technical Support at 1-800-519-8794.

Other manuals for Navien NPE-240A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Navien NPE-240A and is the answer not in the manual?

Navien NPE-240A Specifications

General IconGeneral
TypeTankless
Fuel TypeNatural Gas or Propane
Energy Factor0.97
Energy Efficiency97%
Voltage120V
Ignition TypeElectronic
Maximum Input199, 900 BTU/h
Water Connection Size3/4"
Gas Connection Size3/4"
Warranty15-year on heat exchangers, 5-year on parts, 1-year on labor
Dimensions17.3" W x 13.2" D x 27.4" H

Related product manuals