NCR RealPOS 60 Terminal Site Preparation 31
Electrical Requirements
7601 Terminal Power Requirements
The terminal's external power supply has a maximum output of 150 Watts and provides
power to the terminal and its powered peripherals.
Range Nominal Vrms Minimum Vrms Maximum Vrms Input Current Max. Arms
LOW (115)
100-127 90 136 2.2A
HIGH (230) 200-240 180 265 1.2A
Caution: Locate the power supply away from other electrical equipment, away from
heat sources, away from possible liquid spills, and where there is adequate clearance for
cooling.
Note: The RealPOS 60 does not offer an AC convenience outlet for CRT power. A
separate country-specific power cord must be ordered separately. Available NCR power
cords are described in the System Cables section.
Peripheral Power Requirements
The number of peripherals that the terminal can support is dependent upon which
peripherals are connected. For planning purposes, use the RealPOS 60 (7601) Release 1.0
Power Matrix (B005-0000-2404) for details on total power distribution.
Note: This file requires Microsoft Excel to run.
AC Store Wiring Requirements
The customer must provide suitable AC power for the terminals, associated equipment,
and devices. We recommend a dedicated unswitched power line dedicated to the NCR
equipment installation. Refer to the NCR Workstation and Peripherals AC Wiring Guide
(BSTO-2115-53) for store AC wiring requirements. The AC outlet must be installed near
the terminal and easily accessible to the operator.