NCRSelfServ™84Walk‐UpATMSitePreparation
7‐1CableRequirements
CABLEPREPARATION
NCRsupplyapowercablefortheATM.Otherexternalcablesarenotsupplied.
Specificationsforthesecablesaregiveninthissection.
Itisthecustomer’sresponsibilitytohaveanyrequiredexternalcablesinstalled
andtomakesurethatallcablepreparationscomplywithNCRspecificationsas
wellaswith
allnational,stateorlocaltelephoneandtelegraphregulationsand
laws.
Whenproducingcablesallowfor2.2m(7.22ft)ofcablewithintheATM.
DATALINETRANSIENTPROTECTION
Voltagetransients,linenoise,surges,sags,impulses,andspikesmaybe
experiencedroutinelyorsporadically.Whensuchphenomenaoccurtheuseof
protectivedevicesmayberequiredtoensureproperoperationofthe
equipment.
Itistheresponsibilityofthecustomertoinstallandconnectadataline
transientsuppressionsystem
tocorrectorpreventanydeficiencies.Such
systemsmustmeetthefollowingminimumrequirements:
Beoftheself‐recoveringvoltagelimitingtype.Exhibita‘shortcircuit’mode
uponitsfailuretoensureapositiveindicationofitsfailure.Insertminimum
inductiveandcapacityloadingattheoperatingfrequency.Beinstalledin
accordancewithallapplicablelocal,state,andnationalelectricalcodesand
regulations.
Protectthedataportfromdamageinthepresenceofadatalinetransient
eventasdefinedinIECStandard1000‐4‐5(formerlyIEC801‐5).
ALARMINTERFACECABLES
TheATMmayoptionallybeconfiguredtoprovideanalarminterfacewhich
enablestheATMtobeconnectedtoanexternallocalalarmsystem.The
interfacemaytaketheformofoneoftwooptions;abasicalarmsystemoran
enhancedalarmsystem.
Astabilised,non‐interruptiblepowersupplymust
beprovidedthroughthe
externalalarmsystem.Thealarminterfacecablewiringmustconformtothe
followingspecification:
12V±2Vdc
200mAmaximum
Ripple,5%maximum.
BasicAlarmCable
Removea20mm(0.79in.)sectionoftheoutersleeve,100mm(3.94in.)from
theATMendofthecable.
Takecarenottocutthroughthecableshielding.
EnhancedAlarmCable
Removea20mm(0.79in.)sectionoftheoutersleeve,100mm(3.94in.)from
theATMendofthecable.
Takecarenottocutthroughthecableshielding.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1, 2, 5, 6
3
4
1. Connector, 25 Way (NCR part no. 006-0005896)
2. Terminal, wire, female (NCR part no. 009-0002640)
3. Cable, multiconductor (determined by the alarm installed).
4. Connector (determined by remote device).
5. Shell Hood (NCR part no. 006- ).
6. Screw retainer (NCR part no. 601-0101584).
1500038
Chassis GND
Silent Alarm Common *
Door Alarm N.O.
Door Alarm N.C.
Common
+12V
Silent Alarm N.O. *
Silent Alarm N.C. *
Door Alarm Common
N.O.
N.C
+12V Return
Vibration/Heat
Vibration/Heat
Vibration/Heat
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
* Optional
20 mm
(0.79 in.)
100 mm
(3.94 in.)
1, 2, 5, 6
3
4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1. Connector, 25 Way (NCR part no. 006-0005896)
2. Terminal, wire, female (NCR part no. 009-0002640)
3. Cable, multiconductor (determined by the alarm installed).
4. Connector (determined by remote device).
5. Shell Hood (NCR part no. 006- ).
6. Screw retainer (NCR part no. 601-0101584).
1500038
Chassis GND
Test Transmitter A
Tamper Alarm N.O.
Tamper Alarm N.C
Silent Alarm Common *
Door Alarm N.O.
Door Alarm N.C.
Composite Attack Common
+12V
Test Transmitter B
Tamper Alarm Common
Silent Alarm N.O. *
Silent Alarm N.C. *
Door Alarm Common
Composite Attack N.O.
Composite Attack N.C
+12V Return
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
* Optional
20 mm
(0.79 in.)
100 mm
(3.94 in.)