SiteRequirements
NCRSelfServ™84WalkUpATMSitePreparation
5‐2
TEMPERATUREANDHUMIDITY
Continuousoperatingatorneartherangelimits,orinalocationwherethe
temperatureandhumiditychangebeyondthespecification,shouldbeavoided.
Ifinstallingthoughanexteriorwall,thesitemustmeettherequirementsof
boththeInteriorandExteriorenvironments.
Note: ForexteriorthroughthewallATMsthehumidity
insidethebuildingis
restrictedtoamaximumof30%atanoutsidetemperatureof35°C
(31°F),withalinearrelationshipbetweentemperatureandhumidityto
amaximumhumidityat0°C(32°F).
NormalOperatingRange(InteriorEnvironment)
Temperature:0°Cto40°C(32°Fto104°F)
RelativeHumidity:20%to80%
DewPointTemperatureRestriction:26°C(79°F)maximum
NormalOperatingRange(ExteriorEnvironment)
Temperature:
withoutPassbookPrinter:35°Cto50°C(31°Fto122°F)
withPassbookPrinter:0°Cto40°C(32°Fto104°F)
RelativeHumidity:
withoutPassbookPrinter:10%to100%
withPassbookPrinterfitted:10%to80%
DewPointTemperatureRestriction:26°C(79°F)maximum
StorageRange(UpToThreeMonths)
Temperature:10°Cto50°C(14°Fto122°F)
RelativeHumidity:10%to90%
TransitRange(UpToOneWeek)
Temperature:40°Cto60°C(40°Fto140°F)
RelativeHumidity:5%to95%
ExtremePowerOnRange(UpToOneHour)
Temperature:0°Cto45°C(32°Fto113°F)
RelativeHumidity:10%to95%
BAROMETRICPRESSURE
Operating/TransitLimits:105kPa(15.2lbf/in
2
.)to70kPa(10.2lbf/in
2
.)
EquivalentAltitude:Uptoamaximumof3000m(9842.52ft)