NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved
B006‐7519‐G000
NCRSelfServ™84Walk‐UpATMSitePreparation
5‐1SiteRequirements
POSITIONINGTHEATM
TheATMmaybeinstalledthroughanysuitableexteriorwallorvestibule
location.
IftheATMisfittedwithaPassbookPrinter,itshouldneverbeexposedtorain
andthereforeonlysui table forinteriorinstallations.
TheATMmustalsobepositionedawayfromheatsourcesoranyair
conditioningequipment.
Bright
lightsandwindowsb e hindtheusermaydegradecameraperformance.
PositiontheATMawayfromdirectsunlight.
Allowsufficientroomforinstallationandservicingrequirements.
FLOOR
TheATMmustbeinstalledonalevel,even,concreteorothernoncombustible
surface.Inlocationswherethefloormaybeuneven,itisrecommendedthata
steelplateisusedundertheATM.
Anantistaticfloorcoveringshouldbeusedandmustbeofatypethatwillnot
generate
dustorfluff.
TheATMmustbeinstalledonafloorcapableofsupportingthemaximum
weightincludingmedia.Onlythemaximumweightshouldbeconsideredas
additionaloptionsmaybeaddedafterinstallation.Floorloadingiscalculatedby
dividingthemaximumweightoftheATMbythesurfaceareaof
theATMbase
incontactwiththefloor.
Serviceareas,ATMweightsandfloorloadingforyourATMcanbefoundinthe
VariantDetailssections.
DOORWAYSANDCORRIDORS
Makesurethatdoorwaysandcorridorsleadingtoyourpointofinstallationare
wideenoughtoallowthepackagetopassthrough,ormakearrangementsto
unpacktheATMandremoveitfromthepalletinanareawithsufficientaccess
thenmoveittotheinstallationsite.
Makesurethat
anycorridorscansupporttheweightoftheATM,includingall
packagingandthepallet.
WALL
A25mm(1.0in.)widesmoothsurfaceisrequiredaroundtheedgeofthewall
openingtoenableagoodweatherseal.
WallCavity
Anycavityinthewallmustbesealedtoprovideaflushsurfacethatdoesnot
extendintothewallopening.LeavethegapbetweentheATMsleeveandthe
wallopeningcleartoallowairatroomtemperaturetocirculate.
InstallingThroughaGlassWall
IfyouareinstallingyourATMthroughaglasswallyoumayrequireasuitable
glasssupport(normallyasteelcollar)tositbetweentheATMcollarandthe
glass.Therequirementforthissupportshouldbedeterminedbythearchitect.
Ifrequired,anysuchsupportshouldbesourcedlocally.
CollarTolerance
Thecollar hasatoleranceof±4mm(0.2in.(±0.5°))atthetopandbottom,with
0mm(0.0in.(0°))atitscentre.
Thecollarcannotaccommodatelargedipsordepressionsinthewall.Make
surethewallissmoothandeven.
AMBIENTLIGHTING
IftheATMisfittedwithacamera,itisstronglyrecommendedthatthereisa
minimumof50LUXlightingatfloorlevelwithintheareaillustratedbelow.
TASKLIGHTING
Aminimumof200LUXisrequiredfortasklighting.
0 mm
(0.0 in.)
± 4 mm
(0.16 in.)
± 4 mm
(0.16 in.)
1500 mm
(59.1 in.)
1000 mm
(39.4 in.)