Loading...
NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved
B0067519G000
VariantDetails‐CENI,Standard CollarATM
NCRSelfServ™84WalkUpATMSitePreparation
9‐4
HOLEINTHEWALL
HoleatOptimumHeight
Thisheightassuresthebestdisplayviewabilityforablebodiedpeople.Itdoes
NOTcomplywiththelowered heightregulationslistedinthenextsection.
4HighSecurityEnclosure
5HighSecurityEnclosure
HoleatLoweredHeight
Itistheresponsibilityoftheowninginstitutiontomakesurethattheheight
fromthesidewalkleveltothehig hestoperablepointonthefacia(see‘Facia
Items’)complieswithanylocalregulations.Theinformationcontainedinthe
followingtablesincludethemaximumplinthheightsforthecountrieslisted
andaresho
wnasexamples.
Forcorrectinstallationheightyoumustconsiderthedifferenceinheight
betweenthesidewalkandtheinteriorfloor,andinstalltheATMonaplinthif
necessary.
NotethatCENcertifiedsecurityenclosuresmusthaveaCENcertifiedplinth.
StandardCollar
Short Sleeve - maximum (7.99 in.)
Long Sleeve - maximum (12.99 in.)
203 mm
330 mm
534 mm
(21.02 in.)
368 mm
(14.49 in.)
18 mm
(0.71 in.)
*625 mm
(24.61 in.)
1026 mm
(40.39 in.)
Hole in Wall
ATM Base
View from
Inside Building
Plinth
Sidewalk
*increase to 635 mm (25.00 in.) if ATM installed with cash camera
Short Sleeve - maximum (7.99 in.)
Long Sleeve - maximum (12.99 in.)
203 mm
330 mm
534 mm
(21.02 in.)
B
18 mm
(0.71 in.)
*625 mm
(24.61 in.)
A
Hole in Wall
ATM Base
View from
Inside Building
Plinth
Sidewalk
*increase to 635 mm (25.00 in.) if ATM installed with cash camera
Installation Height - ATM with no modules above touchscreen
UK (CAE Parallel Approach)
4 High with 15 in.
Touchscreen
5 High with 15 in.
Touchscreen
4 High with 19 in.
Touchscreen
5 High with 19 in.
Touchscreen
A - Bottom of hole
847 mm
(33.35 in.)
847 mm
(33.35 in.)
734 mm
(28.90 in.)
776 mm
(30.55 in.)
B - Plinth height
189 mm
(7.44 in.)
71 mm
(2.80 in.)
76 mm
(2.99 in.)
0 mm
(0 in.)
USA (ADA)
4 High with 15 in.
Touchscreen
5 High with 15 in.
Touchscreen
4 High with 19 in.
Touchscreen
5 High with 19 in.
Touchscreen
A - Bottom of hole
846 mm
(33.31 in.)
846 mm
(33.31 in.)
803 mm
(31.61 in.)
803 mm
(31.61 in.)
B - Plinth height
188 mm
(7.40 in.)
70 mm
(2.76 in.)
145 mm
(5.71 in.)
27 mm
(1.06 in.)
Canada & Australia (CSA Parallel Approach)
4 High with 15 in.
Touchscreen
5 High with 15 in.
Touchscreen
4 High with 19 in.
Touchscreen
5 High with 19 in.
Touchscreen
A - Bottom of hole
CANADA
827 mm (32.56 in.)
AUSTRALIA
759 mm (29.88 in.)
CANADA
827 mm (32.56 in.)
AUSTRALIA
776 mm (30.55 in.)
759 mm
(29.88 in.)
776 mm
(30.55 in.)
B - Plinth height
CANADA
169 mm (6.65 in.)
AUSTRALIA
101 mm (3.98 in.)
CANADA
51 mm (2.01 in.)
AUSTRALIA
0 mm (0 in.)
101 mm
(3.98 in.)
0 mm
(0 in.)
Installation Height - ATM with modules above
touchscreen
UK (CAE Parallel Approach)
4 High with 15 in.
Touchscreen
5 High with 15 in.
Touchscreen
A - Bottom of hole
719 mm
(28.31 in.)
776 mm
(30.55 in.)
B - Plinth height
61 mm
(2.40 in.)
0 mm
(0 in.)
USA (ADA)
4 High with 15 in.
Touchscreen
5 High with 15 in.
Touchscreen
A - Bottom of hole
788 mm
(31.02 in.)
788 mm
(31.02 in.)
B - Plinth height
130 mm
(5.12 in.)
12 mm
(0.47 in.)
Canada & Australia (CSA Parallel
Approach)
4 High with 15 in.
Touchscreen
5 High with 15 in.
Touchscreen
A - Bottom of hole
CANADA
769 mm (30.28 in.)
AUSTRALIA
759 mm (29.88 in.)
776 mm
(30.55 in.)
B - Plinth height
CANADA
111 mm (4.37 in.)
AUSTRALIA
101 mm (3.98 in.)
0 mm
(0 in.)
DO NOT USE
N
OT USED