NCRProprietaryInformation‐nottobedisclosedorreproducedwithoutwrittenconsent.©2017,2018byNCRCorporation,Atlanta,Georgia,U.S.A.http://www.ncr.com.AllRightsReserved
B006‐7519‐G000
CableRequirements
NCRSelfServ™84Walk‐UpATMSitePreparation
7‐2
REMOTESTATUSMONITOR
Theremotestatusmonitorfeatureissuppliedasacompleteassembly
consistingofastatusindicatorunit,76.2m(250ft)ofcableandaconnector.
Removea20mm(0.79in.)sectionoftheoutersleeve,70mm(2.76in.)from
theATMendofthecable.
Takecarenotto
cutthroughthecableshielding.
ShorteningtheCable
Ifyouneedtoshortenthecable,proceedasfollows:
1. Removethecoverfromtheremotestatusindicatorunit
2. Disconnectthefourleads(E1,E2,E3andE4)fromtheindicator
3. Cutthecabletotherequiredlengthandstripthefourwireends
4. Connectthewirestothecorrectterminals
5. Replacethe
statusindicatorcover.
REMOTERELAYCABLE
Theremoterelayprovidesapairofopencontacts,ratedat28voltsperampere
forbothacanddcsupplies,whichcanbeclosedtoactivatearemotedevice.
Theinterconnectingcabletoaremotedevicemustconformtothefollowing
specificationandwiring:
Removea20mm(0.79in.)
sectionoftheoutersleeve,100mm(3.94in.)from
theATMendofthecable.
Takecarenottocutthroughthecableshielding.
ETHERNETSTANDARDCABLE
Theethernetstandardcablemustbefullyshielded,8pin,Category5compliant
andmustnotexceed97m(318.20ft)inlength.
Removea40mm(1.57in.)sectionoftheoutersleeve,80mm(3.15in.)from
theATMendofthecable.
Takecarenottocutthrough
thecableshielding.
POWERCABLE
TheATMissuppliedeitherasa120Vora220‐240Vunit.
120VATMsaresuppliedwithapowercablefittedwithaNEMAtype5‐15P
powersourceconnector.
220‐240VATMsaresuppliedwithanunterminatedpowercable.Information
aboutsuitablepowerconnectorsissuppliedwiththeaccessories.
Thepowercablesuppliedis3m(9.84ft)inlength.Ifitisnecessarytoincrease
thislengthtomeetsiterequirements, thentheextensionmustsatisfylocalor
countryregulations.
WARNING Thisequipmentmustbeearthed.
70 mm
(2.76 in.)
20 mm
(0.79 in.)
(Green) E1
(Red) E2
(White) E3
(Black) E4
Red
Yellow
Green
1
2
1, 2
3
4
Rl1
RL2
1. Connector, 2 way Mate-N-Lock (NCR part no. 007-9814285).
2. Terminal wire, male (NCR part no. 007-2009663).
3. Cable, multiconductor (NCR part no. 006-5800006).
4. Connector (determined by remote device).
20 mm
(0.79 in.)
100 mm
(3.94 in.)
40 mm
(1.57 in.)
80 mm
(3.15 in.)