EasyManua.ls Logo

Neat IOR - Connecting Alarm Transmitters; Programming Transmitters

Neat IOR
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Connecting an Alarm Transmitter to IOR
The IOR output can be activated from an alarm transmitter such as
ATOM or INKA. If an ATOM is programmed into IOR, the IOR output will
be activated each time the button on that ATOM is pressed.
Up to 8 different alarm transmitters can be programmed into the same
IOR. Only alarm transmitters that have been programmed into an IOR
will activate its output (see foot-note).
To program an alarm transmitter into IOR, follow these steps:
1. Choose a transmitter number
X between 1 and 8. Two alarm
transmitters can not have the same transmitter number in one
IOR.
2. Remove the lid of the IOR. Press and hold the button inside IOR
while switching IOR on.
3. Wait until the LED inside IOR flashes
X times and then release the
button.
4. Activate the alarm transmitter.
5. The LED inside IOR flashes once to indicate that the radio code
from the alarm transmitter is stored.
Note: Using IOR Programmer, IOR can be configured so that all alarm receivers will
activate its output, also those that are not programmed into IOR, see page 7.