SLT Timers
Quick Install Guide SL2100 Terminals Type B rev 1.0 23
Dial Pulse
The signalling type can be setup for each SLT port within PCPro Easy Edit Extensions Extension Single
Line Telephone SLT SLT Basic Setup.
Dial Pulse telephones are usually 10pps (pulses per second) with a break period of 66mS & make period of
34mS.
Loop Current
Break 66mS
Make
34mS
The default settings of the SL2100 will detect a break period between 10~100mS and a make period of
10~50mS.
Description
Function
Default
Minimum Break Time
The minimum duration of a
dial pulse break
2
(10mS)
Maximum Break Time
The maximum duration of a
dial pulse break
10
(50mS)
Set to 13 (65mS) when TBR is required
Minimum Make Time
The minimum duration of a
dial pulse make
2
(10mS)
Maximum Make Time
The maximum duration of a
dial pulse make
20
(100mS)
Note The setting of the Maximum Break Time is reduced to 13 (65mS) to allow the detection of Timed Break
Recall (TBR).
Note - You must set the Maximum Break Time for Dial Pulse to a value less than that of the Minimum Hook
Flash Time otherwise the system will not detect Timed Break Recall.
Signalling type for SLT’s:
DTMF or DP